Bechtop low speed refrigerated centrifuge
TDL-6 Benchtop low speed refrigerated centrifuge
 
		    
			Technique Parameter
| Model number | TDL-6 | 
| Max Speed | 6000 rpm | 
| Max RCF | 5120 xg | 
| Max Capacity | 4x250ml (4000 rpm) | 
| Speed Accuracy | ±10 r/min | 
| Temp Accuracy | ±1℃ | 
| Temp Range | -20℃~40℃ | 
| Timer Range | 1min~99H59 min/inching | 
| Noise | ≤60 dB(A) | 
| Power Supply | AC 220V 50HZ 15A | 
| Dimension | 640x560x390( LxWxH)mm | 
| Weight | 80 kg | 
| Power | 1.2 KW | 
Rotor Technical Data
| Rotor | Capacity | Max Speed | Max RCF | |
| NO.1 Swing-out Rotor | 4x100ml | 5000rpm | 4650xg | |
| 4x50ml | ||||
| NO.2 Swing-out Rotor | 32x15ml | 4000rpm | 2980xg | |
| 8x50ml | ||||
| 8x100ml | ||||
| NO.3 Swing-out Rotor | 
 | 4x250ml | 4000rpm | 2980xg | 
| Adaptor | 8x50ml | |||
| 4x100ml | ||||
| 36x10ml | ||||
| 40x7ml | ||||
| 20x15ml | ||||
| 48x2-7ml Vacuum blood collection tube | 4000rpm | 3100xg | ||
| 64x2-7ml Vacuum blood collection tube | ||||
| NO.4 Microplate Swinging Bucket Rotor | 2x3x96 hole | 4000rpm | 1970xg | |
| NO.5 Fixed-angle Rotor | 60x50ml | 6000rpm | 5120xg | |
| 12x15ml | ||||
TDL-6M/TDL-5M Benchtop low speed refrigerated centrifuge
 
		    
			 
		    
			Features & Advantages
• Easy operation with touch-sensitive LCD
• The parameter setting can be directly digitally inputted and accurately put in single digit.
• Intelligent status prompt can display instrument status in real time.
• The machines adopts Three-axis gyroscope to monitor the whole dynamic balance.
• Large storage space can store up to 1000 program groups,1000 usage records and 1000 fault records.
• With time display function, including year, month, day, hour, minute and second, which is convenient to trace the usage record.
• Two timing methods are available:Hour/Minutes or Minutes/Seconds.
• Two timing models are optional: count or countdown
• 40 levels of acceleration and deceleration and can set the model of free stop.
• The speed, RCF and temp.curves are displayed on the same screen, and the change relationship can be seen clearly.
• Password lock function:Users can set a password to lock machine and parameter to prevent others from changing.
• Speed and RCF can be automatically converted and displayed in one screen.
• 22 kinds of protection functions such as over-speed, over-pressure, over-heat and so on. Prompt function with voice and text simultaneously
• With electronic manual which can never lost and easy to use
Technique Parameter
| Model number | TDL-6M | TDL-5M | 
| Max Speed | 6000r/min | 5000 r/min | 
| Max RCF | 5200xg | 5200 xg | 
| Max Capacity | 4x750ml(4000rpm) | |
| Speed Accuracy | ±10 r/min | |
| Temp Accuracy | ±1℃ | |
| Temp Range | -20℃~40℃ | |
| Timer Range | 1min~99H59 min/inching | |
| Noise | ≤60 dB(A) | |
| Power Supply | AC 220V 50HZ 15A | |
| Dimension | 600x680x420(LxWxH)mm | |
| Weight | 108kg | |
| Power | 1.5 KW | |
Rotor Technical Data
| Rotor | Capacity | Max Speed | Max RCF | |
| NO. 1 Swing-out Rotor | 4x100ml | 5000rpm | 4650xg | |
| 4x50ml | ||||
| NO. 2 Swing-out Rotor | 32x15ml | 4000rpm | 2980xg | |
| 8x50ml | ||||
| 8x100ml | ||||
| 48x2-7ml Vacuum blood collection tube | ||||
| 64x2-7ml Vacuum blood collection tube | ||||
| NO.3 Swing-out Rotor | 4x250ml | 5000rpm | 5200xg | |
| Adaptor | 8x50ml | |||
| 4x100ml | ||||
| 36x10ml | ||||
| 40x7ml | ||||
| 20x15ml | ||||
| NO.3 Swing-out Microplate Rotor | 2x3x96 holes | 4000rpm | 1970xg | |
| 
 NO.5 Swing-out Rotor | Round hang cup | 4x500ml | 4200rpm | 3550xg | 
| Adaptor | 12x50ml | |||
| 36x15ml | ||||
| 76x7ml Vacuum blood collection tube | ||||
| Swinging bucket rotor | 20x50ml | |||
| 40x15ml | ||||
| 80x10ml Vacuum blood collection tube | ||||
| 112x2-7ml Vacuum blood collection tube | ||||
| 100x1.5ml | ||||
| Hang cup | 148x5ml RIA tube | |||
| 96x2-7ml Vacuum blood collection tube | ||||
| Microplate rack | 4x2x96 holes | |||
| 
 | Conical bottom swing-out rotor | 4x250ml | 4000rpm | 3400xg | 
| NO. 6 Swing-out Rotor | 4x750ml | 
 4000rpm 
 | 3500xg | |
| Adaptor | 12x100ml | |||
| 20x50ml | ||||
| 48x15ml | ||||
| 96x2-7ml Vacuum blood collection tube | ||||
| NO. 7 Swing-out Rotor | 6x250ml | 4000rpm | 3580xg | |
| NO. 8 Fixed-angle Rotor (Suitable for TDL-6M) | 6x50ml | 6000rpm | 5120xg | |
| 12x15ml | ||||
 
			               













 
							 
							 
							 
							 
							 
							 
             
            